  1. Grounding using plastic boxes? - DIY Home Improvement Forum

    Jan 4, 2009 · The bare ground wire connects to any conductive material, like the metal yokes on the recepticals and switches with the green ground screw and runs back to the ground bar in the service panel and then, most likely to grounding rod(s). This is to protect any parts of equipment from becoming energized in the event of a short.

  2. Self grounding receptacle in a metal box? - DIY Home …

    Dec 9, 2020 · Especially if you are using the metal junction box as a self-made "extension cord" because if that box comes into contact with moisture getting an electric shock is a high probability. It is even more important to use the grounding screw on …

  3. Water coming from underground service conduit

    Jul 27, 2022 · Why would water be following the underground pipe from the transformer box?? How about an extension / riser in there, to prevent water from getting in the underground pipe in the first place. Or sealing that pipe right there in the transformer box. To keep the water out. Versus a DIY remedy like a junction box with exit trap.

  4. Daisy chain ground wire - DIY Home Improvement Forum

    Feb 8, 2021 · All the grounds coming from all the cables coming into the box MUST go together. They are not spares; you don't use one of them. They must connect to each other. They must also go ONE of the following: - (if the box is metal) to the metal box. From the metal box, ground will be carried to the switch via its mounting screws and its metal yoke.

  5. ANSWERED. Missing from the 200 A main panel - DIY Home …

    Nov 28, 2024 · The Grounding Electrode Conductor (GEC) which connects a driven rod electrode to the meter socket enclosure is not required by the US National Electric Code (NEC) Some utility Service Standards, as approved by the State's Utility Regulating Agency, require that one (1) such driven rod grounding electrode GEC be terminated there. Were that is ...

  6. Add a new neutral bus bar | DIY Home Improvement Forum

    May 12, 2017 · I’m looking to add a new circuit to my electrical panel. There is plenty of space for the new breaker, but the neutral / ground bar is totally full. That’s not a big deal for the ground wire as you can have more than one ground wire to a screw. But it …

  7. Need advice for ground wire connection in metal box

    Nov 28, 2021 · I initially plan to just use the EMT conduit and metal box as ground without running ground wire, but some people here recommend running one ground wire just for another level of protection. As shown in the picture, there are two 240v circuits with additional 120v circuits sharing the 3/4 conduit.

  8. Old Service Panel with NO Ground Bar - DIY Home Improvement …

    May 8, 2014 · I look at a customer's Murray electric service panel. There is only one bar at the right hand side of the service panel where neutral wires are connected, and hot wires are connected to the circuit breakers. There is no bar at the service panel to connect ground wires for each circuit. The...

  9. Should I use electrical dielectric grease on the...

    Dec 13, 2024 · 2/0 copper wire in from the service mast and the same wire to my panel. The old meter box and socket are being replaced. When opened, I saw that the copper wires were slightly oxidized, but the faces of the clamping screws were corroded. I’ve wire brushed the copper wires and installing a new meter socket. Dielectric grease on the wires and ...

  10. No earth ground on electrical panel - DIY Home Improvement …

    Jul 16, 2016 · If there is a bare ground exiting under the brick by the ground rod, simply re-attach it. If it has been cut and will not reach the rod, run new from panel. Don't eliminate the tv ground.If you run new wire attach to ground bar in panel anywhere except bonding screw, assuming this is your main panel